Return Duct Size for HVAC Unit Sizing Chart & How-to Guide

return air duct design

Fans within plenums and cabinets or next to walls should be located so that air may flow unobstructed into the inlets. Fan performance is reduced if the space between the fan inlet and the enclosure is too restrictive. System effect coefficients for fans in an enclosure or adjacent to walls are listed under Fitting ED7-1. How the airstream enters an enclosure in relation to the fan inlets also affects fan performance. Plenum or enclosure inlets or walls that are not symmetrical with the fan inlets cause uneven flow and/or inlet spin. Entries and converging junctions are only in the exhaust/return portion of systems.

return air duct design

How Return Air Vent Location Impacts HVAC Efficiency

The cost to replace ductwork in a basement is $1,800 to $3,100 on average. Basement ductwork replacements are typically the cheapest since the ducts are easy to access. The following table shows the average cost to replace ductwork. CFM Room by Room – It’s important to know what diameter  or capacity ducts are needed for each room, and knowing the CFM of air flow it needs is the place to start. Each fitting is rated with a number representing the amount of friction it causes in feet of ductwork equivalency. Factors are the shape of the fitting, such as a 90-degree or 45-degree bend, but also how many pieces it is.

3 DUCTWORK SECTIONAL LOSSES

Figure 13 shows deficient fan performance resulting from poor inlet and outlet connections to ductwork. Point 1 is the fan/system operating point without taking into account poor inlet and/or outlet conditions. Point 2 is the system operating point when the apparent resistance of poor connections is included in the calculations. Point 4 is the operating point on the original fan performance curve, taking into consideration the apparent system resistance of poor fan/system connections. Point 3 is the fan operating point on the original system curve when the apparent resistance of poor inlet and/or fan connections is not taken into account.

Is It OK to Close Off a Return Air Vent?

Keep in mind that you need to maintain a certain duct height regardless of the airflow. If you read my post on supply air diffuser sizing, you’ll understand why. From the chart, we can see that 12″ duct results in the velocity exceeding 700 fpm. Although the friction loss is below 0.1 inch of water per 100 feet, the high velocity could lead to noise. Again, slightly higher velocity may not have a noticeable difference.

What size return duct do I need for a 3 ton?

In addition, the SR sizes are slightly larger, and thus potentially less noisy. Both methods have static regain, but the SR design uses the regain more efficiently. Use Figure 19 for preliminary sizing of air intake and exhaust louvers. For air quantities greater than 3300 L/s per louver, the air intake gross louver openings are based on 2 m/s; for exhaust louvers, 2.5 m/s is used for air quantities of 2400 L/s per louver and greater. These criteria are presented on a per-louver basis (i.e., each louver in a bank of louvers) to include each louver frame.

HVAC Return Air Ducting - You Better Have One in Many Rooms

An HVAC system blows air into the building, and without a return air duct, that excess air would have nowhere to go. If the air pressure in a building is unbalanced, the excess air may be pushed outside, which doesn’t help maintain the desired temperature. The total cost to replace ductwork depends on the house size, duct location, number of ducts, duct type, and insulation. Labor costs increase for rerouting ductwork, cutting into the floor or ceiling, or installing ducts in older homes. Lower the acceptable maximum friction rate by about 25%, which, as the calculator will show, requires ducts with larger diameter / total capacity. Understanding what noise is and how to control it is fundamental to duct design.

Remember I mentioned earlier, all the diffuser neck size is 150mm (6″) and thus, all the flexible duct size is also 150mm (6″). Hence, I don’t really indicate the size in the layout drawing. Also, you want to place the supply and return grille in symmetry so that they look good. Furthermore, try not to put any supply air diffuser too close to hot windows to avoid condensation. The location of the supply and return grille determines how you will run the supply and return duct. So, draw the supply and return grille on your layout drawing.

Debunking Myths: The Truth About Return Air Vents

One bad connection can reduce fan performance below its rating. Dynamic losses result from flow disturbances caused by duct-mounted equipment and fittings that change flow direction (elbows), area changes (transitions), and converging/diverging junctions. For a detailed discussion of hydraulic networks, consult Idelchik et al. (1994). Equations (18) and (19) must be used to determine pressure loss. In other words, you have to do some work to get the equipment sized right. Tables and charts have been around for years that convert these measurements into BTUs.

Fresh Air Systems - Balanced Whole House Ventilation - Zero Energy Project

Fresh Air Systems - Balanced Whole House Ventilation.

Posted: Mon, 27 Jun 2022 07:00:00 GMT [source]

In all cases, thermal insulation should meet local code requirements. Insulation thicknesses in these standards are minimum values; economic and thermal considerations may justify higher insulation levels. Additional insulation, vapor retarders, or both may be required to limit vapor transmission and condensation. When wind is perpendicular to the upwind wall, air flows up and down the wall, dividing at about two-thirds up the wall. The downward flow creates ground-level swirl that stirs up dust and debris. If ground-level sources are major sources of contaminants, rooftop intake is desirable.

Representative production-run louvers were used in establishing Figure 19, and all data used were based on AMCA Standard 500-L tests. For louvers larger than 1.5 m2, the free areas are greater than 45%; for louvers less than 1.5 m2, free areas are less than 45%. Unless specific louver data are analyzed, no louver should have a face area less than 0.4 m2. If debris can collect on the screen of an intake louver, or if louvers are located at grade with adjacent pedestrian traffic, louver face velocity should not exceed 0.5 m/s. Duct insulation for new low-rise residential buildings should comply with ASHRAE Standard 90.2. Existing buildings should meet requirements of ASHRAE Standard 100.

First, if we use a 16″ duct for 600 cfm, it is considered oversized and it is not necessary because we have a smaller size which is 14″ available. When we use a 14″ duct to carry 600 cfm, the resulting velocity is well under the 700 fpm limit. Additionally, we also want to check the friction loss which is indicated by the red dotted line. Generally, we don’t want the friction loss to exceed 0.1 inch of water per 100 feet. For 600 cfm, 14″ duct results in a friction loss of about 0.035 inch of water per 100 feet.

This magic happens because the blood-vessel diameters decreases as they get farther away from your heart. Designing a good ductwork system requires broad HVAC knowledge. With the above steps and examples, I hope by now you can design the ductwork for your home. Without them, you may not have a balanced airflow throughout your home. Meanwhile, your contractor should perform air balancing as well.